Tutorials

Annotating variants: what the main columns mean

What the main variant annotation columns mean, from gene and transcript to consequence, population frequency, ClinVar and predictors, and their limits.

A variant caller tells you that a sample has a different base at a particular position. It does not tell you which gene that position belongs to, whether the change alters a protein, or whether the same change has been seen in other people. Variant annotation adds that context. The output is still a table, though, and the columns are easy to misread. This guide explains what the main annotation columns mean and where their limits lie.

What is already in the VCF

Before annotation, each variant is a row with eight fixed fields: chromosome, position, identifier, reference allele, alternate allele, quality, filter status and an INFO field. Genotypes and per-sample values follow in the FORMAT and sample columns.

QUAL is the caller's confidence that a variant exists at that position, not a measure of how harmful it is. FILTER records whether the variant passed the pipeline's own thresholds. A variant with a high quality score can still be a sequencing artefact, and a variant marked PASS has only passed the filters that were applied. For a column-by-column walk through the format, see the VCF file format guide.

What annotation adds

Annotation tools compare each variant with reference gene models, transcript sequences, population databases and clinical databases. They then write the results into the INFO field, often as a CSQ entry for Ensembl Variant Effect Predictor (VEP) or an ANN entry for SnpEff.

The main annotation tools are VEP, SnpEff and ANNOVAR. They broadly agree on consequence terms because those terms come from the Sequence Ontology, but their defaults, transcript sets and extra databases differ, so compare configurations before comparing outputs.

The columns you will actually use

Column names vary by tool, but most annotation tables contain the same kinds of information:

Column typeWhat it records
Gene and transcriptWhich gene model the variant was mapped to
ConsequenceThe predicted effect on that transcript, such as missense or splice donor
ImpactA coarse severity label supplied by the annotator
HGVSc and HGVSpThe variant written in standard coding and protein nomenclature
Existing variationIdentifiers from databases such as dbSNP
Population frequencyAllele frequencies from resources such as gnomAD
Clinical significanceAssertions recorded in ClinVar
PredictorsScores such as SIFT, PolyPhen-2, CADD or SpliceAI

No single column is a verdict. Annotation describes what a variant could do and what has been reported about it; interpretation combines that evidence with the gene, the disease, the inheritance pattern and the patient.

Gene and transcript: the first ambiguity

A genomic position can fall in more than one gene, and even within one gene, most human genes have several transcripts. The same variant can have different consequences in each. A change may be a missense variant in one transcript, synonymous in another and intronic in a third.

Annotation tools therefore report a consequence per transcript. VEP, for example, reports all overlapping transcripts by default. Many pipelines use --pick or a similar option to keep one line per variant, chosen by a severity ranking or by a preferred transcript. That choice is convenient but not neutral: the selected transcript may be a minor isoform that is not expressed in the tissue you care about.

Where possible, use the MANE Select transcript for clinical reporting, and state which transcript was used. MANE Select provides one agreed representative transcript per protein-coding gene, which makes reports comparable between labs. For research questions about a specific isoform, annotate against that isoform explicitly and say so.

Consequence and impact

Consequence terms come from the Sequence Ontology. Common examples are missense_variant, synonymous_variant, stop_gained, frameshift_variant, splice_donor_variant, splice_acceptor_variant, intron_variant and intergenic_variant.

VEP also assigns a broad impact level: HIGH, MODERATE, LOW or MODIFIER. HIGH includes changes such as stop gains, frameshifts and canonical splice site disruptions. MODERATE includes missense changes. LOW includes synonymous changes. MODIFIER covers non-coding and intergenic variants.

The impact label is a useful sorting device, not a biological conclusion. A HIGH consequence in a gene that is not expressed in the relevant tissue may be irrelevant. A MODIFIER variant in a regulatory element can matter. Conversely, a synonymous change can affect splicing or RNA stability. Treat the label as a prompt to look at the evidence, not as the evidence itself.

Population frequency

Population databases answer a simple question: how often has this variant been seen in presumably unaffected or unselected individuals? gnomAD is the usual reference. Its columns include global allele frequency, frequencies in ancestral populations, the maximum population frequency and counts of homozygotes.

Frequency is one of the strongest filters available for rare disease work, but it has to be used carefully. A variant that is common in one population may be rare globally, so check the relevant ancestry group as well as the overall frequency. Some populations are under-represented in databases, and absence from gnomAD is not proof that a variant is pathogenic. Frequency also depends on the variant type: indels and structural variants are less completely represented than single-nucleotide changes.

Use frequency to exclude variants that are too common to cause a rare Mendelian condition, given the disease model. Do not use it to declare a rare variant causal.

Clinical assertions and computational predictors

ClinVar records interpretations submitted by clinical laboratories. Each assertion comes with a review status, and some variants have conflicting interpretations. A Pathogenic entry with expert-panel review is stronger evidence than a single submitter's classification, but it is still an assertion about a variant, not a diagnosis for your sample. Always check the review status, the condition and the date.

Computational predictors add another layer. SIFT and PolyPhen-2 estimate the effect of missense changes. CADD integrates many annotations into one score. REVEL is designed for missense variants, and SpliceAI estimates splice-altering potential. These tools are correlated with each other and are trained on imperfect labels. They are useful for prioritisation, especially when several agree, but a high score does not establish pathogenicity and a low score does not exclude it. For clinical classification, predictors are supporting evidence within a formal framework, not a replacement for it.

Versions, representation and configuration

Annotation is only reproducible if you record the versions: the genome build, the annotation release, the transcript set and the database versions. A variant annotated against GRCh37 and one annotated against GRCh38 are not directly comparable, and a transcript that is missing from an old release can produce a misleading consequence.

The representation of the variant matters too. Left-align and normalise indels before annotation, split multi-allelic records where the tool expects it, and check that the reference allele matches the genome. If the REF allele does not match, the annotation may be computed for a different variant than the one in your sample. Most annotation tools warn about this, but the warning is easy to miss in a large run.

Reading a row without over-reading it

A sensible order is: confirm the variant and its genotype, identify the gene and transcript, read the consequence, check population frequency, check clinical assertions, then look at predictors. Write down which evidence you used and which thresholds you applied. Keep the raw annotation alongside any filtered table so that another person can retrace your decisions.

The same discipline applies to other data types, where a table of measurements can look more definitive than it is; single-cell matrices have their own version of this problem, covered in your first single-cell RNA-seq analysis.

Key points

  • The VCF fields describe the call, not its medical importance; QUAL and FILTER are not pathogenicity measures.
  • Annotation adds gene, transcript, consequence, frequency, clinical and predictor columns.
  • A variant can have different consequences in different transcripts, so record which transcript you used.
  • Impact labels such as HIGH and MODIFIER are sorting aids, not conclusions.
  • Population frequency is a strong filter but depends on ancestry, variant type and database coverage.
  • ClinVar entries are assertions with review statuses, and computational predictors are supporting evidence.
  • Record genome build, annotation release and database versions with every annotated file.

When to ask for help

If you have an annotated variant list and are unsure which columns to trust, or if two annotation runs disagree, an analyst can check the transcript choice, the normalisation and the database versions before you build a report on top of them. You can order an analysis or discuss a project through our WGS and WES variant analysis service. If you are still at the calling stage, the variant calling overview explains where annotation fits in the pipeline.

Sources

When to ask for help. If your data or design do not fit a tutorial, order an analysis and we will reply with a fixed price.

Written by the Solagene team for research and education. Found an error? Tell us and we will correct it.