Converting between mass and moles of DNA or RNA is one of the most common calculations at the bench. You need it to set up a ligation at the right insert-to-vector ratio, to load the right number of copies into a qPCR standard curve, and to resuspend an oligo at a known molarity. The formulas are short once you know which one applies.
Average mass per base or base pair
For quick work, use these averages, which already account for the sodium counter-ions in a typical preparation:
| Molecule | Average mass |
|---|---|
| Double-stranded DNA | about 650 g/mol per base pair (some protocols use 660) |
| Single-stranded DNA | about 330 g/mol per nucleotide |
| Single-stranded RNA | about 340 g/mol per nucleotide |
So a 3,000 bp plasmid weighs about 3,000 × 650 ≈ 1.95 × 10⁶ g/mol.
Exact formulas for oligonucleotides
For a short single-stranded DNA oligo with a 5′ hydroxyl (no phosphate), the molecular weight from the base counts is:
MW = (A × 313.21) + (T × 304.2) + (C × 289.18) + (G × 329.21) − 61.96
Example: the 20-mer AGCGTACGATCGGATCCTAG has A = 5, T = 4, C = 5, G = 6, so
MW = 1,566.05 + 1,216.8 + 1,445.9 + 1,975.26 − 61.96 ≈ 6,142 g/mol.
Synthesis companies print a value like this on the oligo datasheet. Modifications such as a 5′ phosphate, a fluorophore or a quencher add their own mass.
From nanograms to picomoles
picomoles = nanograms × 1,000 ÷ (length × mass per base or bp)
For double-stranded DNA with 650 g/mol per bp:
pmol = ng × 1,000 ÷ (bp × 650)
Example: 100 ng of a 1,000 bp PCR product is 100 × 1,000 ÷ (1,000 × 650) ≈ 0.154 pmol, or 154 fmol.
This is what you need for ligations. A 3:1 insert-to-vector molar ratio with 50 ng of a 3,000 bp vector (about 25.6 fmol) needs about 77 fmol of a 1,000 bp insert, which is about 50 ng.
From nanograms to copy number
copies = (ng × 6.022 × 10²³) ÷ (length in bp × 650 × 10⁹)
Example: 1 ng of a 3,000 bp plasmid is (1 × 6.022 × 10²³) ÷ (3,000 × 650 × 10⁹) ≈ 3.1 × 10⁸ copies.
Copy numbers are the basis of absolute qPCR standard curves and of spike-in controls.
Which number to trust
- Averages (650, 330, 340) are fine for routine work and agree within a few percent with exact sequence-based values.
- Use the exact formula for oligos when you need precise molarity, for example in hybridisation assays.
- Your concentration measurement is usually the biggest source of error. A260 readings are affected by RNA contamination, phenol and low volumes; fluorescent dyes specific to dsDNA are more reliable for low amounts.
Common mistakes
- Using the dsDNA value for a single-stranded oligo, which halves the answer.
- Forgetting that a plasmid's length includes the backbone, not just the insert.
- Confusing pmol and fmol by a factor of 1,000.
- Calculating copies from a concentration measured on an impure sample.
Calculate it free
The DNA molecular weight calculator handles DNA and RNA, single- and double-stranded. The ng to pmol converter, DNA copy number calculator and ligation calculator do the conversions above, and all run in your browser.
Learn it properly with Vedicgen
Quantifying nucleic acids, setting up ligations and preparing qPCR standards are hands-on parts of Vedicgen's Molecular Biology Techniques and Gene Cloning & Recombinant DNA courses.
Sources and further reading
- OligoCalc: oligonucleotide properties calculator (Kibbe, Nucleic Acids Res 2007)
- NIST: Avogadro constant
Written by the Solagene team for research and education. Found an error? Tell us and we will correct it.