Molecular dynamics simulates the motion of atoms using a force field. A simulation can show how a structure flexes, how a ligand moves in a pocket or how a mutation changes a local interaction. It cannot prove that a biological process happens in a cell.
What you set up
A simulation needs coordinates, a force field, a solvent model, ions and a set of parameters. The coordinates usually come from an experimental structure, a homology model or a predicted model.
The force field describes bonded and non-bonded interactions. Water is usually represented explicitly, with a water model and a box large enough to avoid interactions across periodic boundaries. Ions neutralise the system and approximate the ionic strength.
Each choice introduces an assumption. A force field parameterised for one type of system may not describe another well. A ligand may need parameters that are not available by default.
Minimisation and equilibration
Energy minimisation removes clashes and unrealistic geometry from the starting structure. It is not a physical simulation; it is a relaxation.
Equilibration brings the system to the target temperature and pressure. It is usually done in stages, with restraints on the protein or the ligand, and then without restraints. A system that is not equilibrated can show drift or instability in the production run.
Check the temperature, pressure, density and energy during equilibration. A sudden change may indicate a problem with the setup.
Production
The production run is the part you analyse. Its length depends on the process. A small conformational change may be visible in a short run; a large transition may need much longer.
A single trajectory is one sample from a stochastic process. Two runs with different initial velocities can give different results. Replicate simulations strengthen a claim.
Analysis
Common analyses include the root-mean-square deviation (RMSD) of the backbone, the root-mean-square fluctuation (RMSF) per residue, the radius of gyration, the solvent-accessible surface area, hydrogen bonds and distances between specific atoms.
An RMSD plot shows whether the structure has stabilised. A plateau suggests a stable conformation; a drift suggests that the structure is still changing or that the simulation is unstable. An RMSF plot shows which regions are flexible. Compare the plateau with the length of the run before treating the trajectory as converged.
Do not over-interpret a single distance. A contact that forms and breaks may be transient. Calculate the distribution over the trajectory and compare it with a control.
What a simulation can and cannot show
A simulation can suggest a mechanism, identify a flexible region or rank a set of poses. It can show that a proposed interaction is geometrically possible.
It cannot prove that a ligand binds with a particular affinity, that a conformational change occurs on a biological timescale, or that a mutation causes a disease. Those claims need experimental evidence or a more rigorous free-energy calculation.
Force-field and sampling limits
The force field is an approximation. It may not capture polarisation, covalent modification or a metal centre accurately. The starting structure may be wrong, and the simulation may stay near the wrong state.
Sampling is limited. A simulation that runs for a short time may not cross a barrier. A result that depends on a rare event needs enhanced sampling or many replicates.
A practical workflow
- Choose the structure and check its quality.
- Choose a force field and a water model.
- Build the box, add ions and neutralise.
- Minimise the energy.
- Equilibrate temperature and pressure in stages.
- Run the production simulation.
- Check stability and convergence.
- Analyse the properties relevant to the question.
- Report the parameters and the limitations.
Choosing the simulation length
There is no universal length. The right length depends on the process and on the relaxation times of the system. A small side-chain rearrangement may be visible in a short run; a loop opening or a larger conformational change may need much longer.
A practical approach is to run a pilot, check whether the properties of interest have stabilised, and extend if they have not. Report the length and the convergence check. A trajectory that is still drifting at the end has not answered the question.
Replicates and controls
Run independent replicates with different initial velocities. If the same behaviour appears in several runs, the result is more robust. If each run gives a different answer, the system is undersampled.
For a mutation, simulate the wild type and the mutant with the same protocol. The comparison is more informative than the mutant alone. For a ligand, compare the complex with the apo protein and, if possible, with a known control.
Reporting
Report the structure source, the force field, the water model, the box size, the ions, the temperature, the pressure, the simulation length, the software and the analysis methods. State the replicates and the convergence checks.
For a figure, show the time series and the distribution, not only a single snapshot. A snapshot is an illustration, not evidence.
Key points
- MD simulates motion under a force field; it is not a direct observation.
- Setup choices affect the result.
- Equilibration is not optional.
- A single trajectory is one sample.
- MD can suggest a mechanism but cannot prove binding affinity.
Common mistakes
- Starting from an unminimised structure with clashes.
- Using a force field without checking ligand parameters.
- Analysing a trajectory that has not equilibrated.
- Treating one short run as a complete sampling.
- Claiming binding affinity from a short simulation.
When to ask for help
If the system contains a metal, a modified residue or a ligand without parameters, or if a simulation is unstable, ask for a review. You can order an analysis or read the docking validation guide. The Molecular Dynamics Simulations course covers setup and analysis, and the GROMACS tutorial gives a worked workflow.
Sources and further reading
Written by the Solagene team for research and education. Found an error? Tell us and we will correct it.