Asking someone to analyse your data is a handover, and like any handover it works better when both sides know what is being passed across. Most delays in collaborative bioinformatics come from missing metadata, unclear questions or files that cannot be matched to samples, not from the analysis itself. This article describes what to send, how to organise it and what to say about the experiment so that the first conversation is about biology rather than file names.
Start with the question
Before listing files, write down what you want to know. "Analyse my RNA-seq data" is not a question. "Which genes differ between treated and untreated cells, and which pathways are enriched among them?" is. "Does the treatment effect differ between the two genotypes?" is a different analysis with a different design requirement.
A clear question determines the comparison, the statistical model and the figures. It also helps the analyst tell you when the data cannot answer it. If you have several questions, rank them. A dataset that supports the primary comparison well may be underpowered for a secondary subgroup analysis, and it is better to know that early.
Include the biological context: organism, tissue or cell type, treatment, time points, genotype and the expected direction of change if you have one. A short paragraph is enough. The analyst does not need the whole grant proposal, but they do need to understand what the samples represent.
The minimum data package
A useful handover usually contains five things:
- The data files, either raw reads or a count matrix.
- A sample sheet that maps every file to its experimental group and covariates.
- The reference and annotation used, or a clear statement that the analyst should choose them.
- The experimental design, including replicates, batches and pairing.
- The question and any prior analysis, so work is not repeated or contradicted.
If any of these is missing, say so rather than guessing. An explicit "we did not record the library batch" is more useful than a sample sheet that implies a batch structure which may not be real.
Files and formats
For raw data, send FASTQ files, one file per read end, with consistent naming. Paired-end data should have R1 and R2 files that match exactly in sample name and read count. Do not rename files in a way that loses the link to the sample sheet, and do not send only trimmed reads unless you also say what trimming was done.
If you already have a count matrix, send the raw counts as a tab- or comma-separated table with gene identifiers in the first column and sample names in the header. Do not send TPM, FPKM or already normalised values for differential-expression analysis; the analyst needs raw counts and will normalise them as part of the model. If you also have TPM values for exploration, send them separately and label them clearly.
For other data types the same principle applies: send the least-processed data you have, plus a description of any processing already applied. A BAM file is useful for visualisation and splicing analysis, but it is not a substitute for FASTQ if the analyst needs to re-quantify. A variant file should come with the reference build and the calling pipeline version. The VCF format guide explains the fields that matter.
Large files are best shared through a controlled link or an institutional transfer service rather than email attachments. If the data are human and identifiable, check your ethics approval and data-transfer agreement before sending anything. The analyst should not have to ask whether the data are allowed to leave your institution.
The sample sheet
The sample sheet is the single most important file in the package. A good one has one row per sample and one column per variable, with no merged cells, no colour coding and no notes hidden in comments. Useful columns are:
- sample_id: a unique, short identifier that also appears in the file names.
- file_1 and file_2: the FASTQ paths or names, for paired-end data.
- condition: the group or treatment, spelled consistently.
- replicate: the biological replicate number within condition.
- batch: extraction, library-prep or sequencing batch, if known.
- pair: the subject or block identifier for paired or matched designs.
- covariates: sex, age, genotype, time point, tissue or any other variable that might affect expression.
- notes: anything unusual about a sample, such as low RNA integrity or a failed lane.
Use a controlled vocabulary. "Control", "control " and "CTRL" will be treated as three groups by many tools. Avoid spaces and special characters in sample IDs. Keep the sheet as a plain text or spreadsheet file, and include a second copy of the key columns in the body of your message so the analyst can see the design at a glance.
The article on batch effects explains why the batch column matters even when you think there is no batch. If condition and batch are the same, the analyst needs to know before they start.
Experimental design and methods
Describe how the samples were generated in enough detail that the analyst can judge what the replicates represent. State whether replicates are biological or technical, how many animals or donors contributed, whether samples were pooled, and whether any samples were excluded before sequencing.
Include the library preparation kit and protocol, read configuration, sequencing platform and approximate depth. These details affect strandedness, duplication, adapter content and the choice of quantification method. If you used a commercial service, send the provider's report as well; it often contains run-level information that is not in your notes.
Also describe any treatment or handling that could create a batch: different days, different operators, different reagents, different machines. These are not confessions of failure. They are covariates, and recording them is what allows the analyst to account for them.
What has already been done
If someone has already analysed the data, say what they did and why you are asking for a second analysis. Send the previous report, the code if available, and the list of samples that were removed. This prevents duplicated work and makes disagreements traceable.
If you have a target gene or pathway, say so, but do not ask for the analysis to be tuned until that gene appears. Exploratory and confirmatory questions should be separated. A result that was found by searching many thresholds is weaker than a result predicted in advance, and a good analyst will want to know which situation applies.
A short brief template
A brief of half a page is usually enough:
- Background: one or two sentences on the system and treatment.
- Question: the primary comparison, plus any secondary questions.
- Design: groups, number of biological replicates, pairing and batches.
- Data: file type, location, reference build and annotation.
- Prior work: what has been done and what remains uncertain.
- Output: the tables and figures you need, and any journal or thesis requirements.
- Constraints: ethics or data-use conditions, and who else needs access.
The analyst can ask follow-up questions from there. The aim is not a perfect document; it is a shared understanding of what the data represent and what would count as an answer.
Key points
- State the biological question and the comparison before listing files.
- Send raw FASTQ or raw counts, not only normalised values.
- Provide a machine-readable sample sheet with consistent sample IDs.
- Record condition, replicate, batch, pairing and covariates explicitly.
- Describe library preparation, sequencing configuration and any prior processing.
- Say what has already been analysed and why a second analysis is needed.
- Check ethics and data-transfer permissions before sharing human data.
- Keep the brief short, but make the design and the expected output clear.
When to ask for help
If you are unsure whether your files and metadata are sufficient, it is reasonable to ask for a review of the package before the analysis begins. A short exchange at that stage prevents most of the back-and-forth later. You can order an analysis or discuss the handover through our RNA-seq analysis service. For a preview of the checks an analyst will run first, see the RNA-seq quality-control checklist; for the analysis itself, the RNA-seq workflow shows what each file is used for.
Sources
- NCBI Gene Expression Omnibus (GEO)
- NCBI Sequence Read Archive (SRA)
- European Nucleotide Archive (ENA)
- FGED Minimum Information about a Sequencing Experiment (MINSEQE)
- Wilkinson et al., The FAIR Guiding Principles for scientific data management and stewardship (Scientific Data, 2016)