Chemistry & structure · Step-by-step guide

Antibody Developability: a step-by-step guide

Antibody Developability identifies CDRs with heuristic Kabat rules and screens antibody sequences for common sequence liabilities. This guide shows how to read the CDR calls, the liability table and the side-by-side comparison.

Before you start

  • VH and VL amino-acid sequences in one-letter code, one chain per line, or a single scFv sequence.
  • The chain names you use internally, so the comparison table is readable.
  • A note that these are sequence rules of thumb, not a validated developability assay.
The app has Demo (two VH) and Demo (two VL) buttons that load published antibody sequences.

Step by step

  1. Open Chains & CDRs and paste your sequences

    Paste VH and VL one chain per line, or a single scFv. The Demo (two VH) and Demo (two VL) buttons load published antibody sequences for practice.

  2. Check that each chain was recognised

    The app labels each chain as VH, VL or scFv and reports an error if a sequence is not recognised as a VH or VL domain. Fix the sequence or the chain label before continuing.

  3. Review the CDR table

    The CDR columns show the heuristic Kabat CDR, its sequence, length and positions. Treat the boundaries as a rule-based annotation, not a numbering-database assignment.

  4. Open Developability and read the liabilities

    The liability table lists deamidation, isomerisation, N-glycosylation sequons, oxidation motifs and free cysteines, with motif, position, region and a risk note.

  5. Read the property panel

    pI, net charge at pH 7.4, GRAVY and CDR composition are reported per chain. These are sequence calculations, not measured stability or solubility.

  6. Compare up to twelve chains

    Open Compare to place candidates side by side. Use the flags to decide which sequences deserve experimental follow-up, not which one is “best”.

How to read the results

OutputWhat it tells you
CDR table (Chain, Type, CDR, Sequence, Length, Positions)Where each CDR was placed and what it contains. A CDR that looks unusually long or short is worth checking against the antibody family.
Liability table (Liability, Motif, Position, Region, Risk)Sequence motifs that can be chemically unstable. “In CDR” matters more for binding; framework liabilities matter more for manufacturing.
Property table (pI, Charge pH 7.4, CDR-H3 length, GRAVY)Calculated physicochemical properties. They help triage, but they do not predict expression, aggregation or stability on their own.
Comparison tableThe same columns for several chains. Look for liabilities shared by all candidates and for properties outside the range you normally work with.

Common problems

The sequence is not recognised as a VH or VL domain.
Check for non-standard residues, missing conserved cysteines or a sequence pasted with numbering or gaps. Provide a clean one-letter sequence.
An scFv is treated as one chain.
The app splits an scFv into its chains only when the linker is recognisable. If it is not, paste VH and VL separately.
A free cysteine is flagged but the antibody is known to be stable.
The flag is a sequence rule, not a measurement. Confirm whether the cysteine is expected (for example in a engineered disulfide) before changing the sequence.
Too many chains for the comparison view.
The app compares up to twelve chains. Split the panel into smaller groups and record which comparison you used.
CDR boundaries differ from a numbering tool.
This app uses published heuristic Kabat rules and has no numbering database. For a formal Kabat, Chothia or IMGT assignment, use a dedicated numbering tool and state which scheme you used.

Limits

  • No numbering database and no structure: CDRs come from heuristic Kabat rules.
  • Developability flags are published rules of thumb, not validated cut-offs.
  • Sequence properties are calculations, not measurements of expression, aggregation or stability.

The app records its tool, version, parameters and input checksum in the methods log. The documentation on reproducibility explains how that record becomes a methods paragraph, and the Report Builder collects the figures into one export.

How to cite this analysis

Cite the Workbench using the Zenodo DOI on the Cite page (/cite). Name the CDR rule set and the liability motifs you screened, and confirm any candidate experimentally. Citation, DOI and BibTeX.

Last reviewed: 2026-11-10. If a screen does not match this guide, the app is the source of truth; tell us so the guide can be corrected.