Compensation corrects for fluorescence from one dye appearing in the detector channel of another. Without it, a single positive population can look positive in several channels and a multicolour panel becomes unreadable.
Why spillover happens
Fluorophores have broad emission spectra. A dye excited by one laser may emit light across a range of wavelengths, and part of that light reaches detectors intended for other dyes. The detector measures a mixture, not a pure signal.
Compensation subtracts a calculated fraction of the signal in one channel from another. The result is an estimate of the true signal in each channel. It is a mathematical correction applied to the data, not a physical separation of the light.
Single-stain controls
Compensation requires a single-stain control for each fluorophore in the panel. The control contains cells or beads stained with one dye and acquired with the same instrument settings as the experiment.
For each single stain, the signal appears mainly in its own channel and partly in other channels. The software uses these spillover values to build a compensation matrix.
The single-stain controls must be bright enough to measure the spillover accurately. A dim stain gives a noisy estimate. They should also use the same sample type as the experiment when possible, because the autofluorescence and the background can differ between cells and beads.
The compensation matrix
The matrix has one row and one column for each fluorophore. The diagonal represents the signal in the correct channel; the off-diagonal entries represent spillover. The software inverts the matrix to correct the data.
A matrix can be calculated automatically or edited by hand. Automatic calculation is a starting point. If a single-stain control is poor, the matrix entry will be poor, and every sample corrected with it inherits the error.
Always inspect the single-stain plots. A clean positive population with a clear negative population is easier to use than a smear. If the positive and negative populations overlap, the compensation will be uncertain.
Spreading error
Compensation can increase the spread of a population. A bright population in one channel, after correction, may show more spread in another channel than the true negative population. This is sometimes called spreading error or spillover spreading.
Spreading error is not a failure of the matrix. It is a consequence of correcting a signal that has Poisson noise. It matters when a dim marker is measured in a channel that receives spillover from a bright marker. The dim positive population may become hard to distinguish from the negative.
Panel design can reduce the problem. Put bright markers in channels with little spillover into the channels used for dim markers. Use a dye with a narrower emission or a different laser if the instrument allows.
Compensation and gating
Compensation should be applied before fluorescence gates are drawn. A gate drawn on uncompensated data may include events that are not truly positive in that channel.
After compensation, re-check the gates. A population that looked clean before may split, and a population that looked positive may become negative. This is expected when the correction is working.
Do not compensate by moving gates. If the compensated data show a real biological pattern, that is the result. If the pattern looks wrong, check the controls and the matrix.
Verification
A useful check is to plot two channels against each other and look at the single-positive populations. After correct compensation, a population that is positive for one marker and negative for the other should sit on the axis, not diagonal.
Another check is to compare the compensated data with a biological expectation. If a cell type should be negative for a marker, and the compensated data show a bright positive population, something is wrong.
Run the compensation controls on the same day and with the same instrument settings as the experiment. A matrix from a different voltage setting is not valid.
When to redo compensation
Redo the single stains if the instrument settings change, if a laser or detector is replaced, or if the panel changes. A small change in voltage can change the spillover.
If the sample has a very different autofluorescence from the control, the matrix may not correct it well. In that case, consider a different control or an instrument setting that reduces the background.
A practical workflow
- Design the panel with spillover in mind.
- Prepare a single stain for each fluorophore.
- Acquire the single stains at the experimental settings.
- Calculate the matrix and inspect each single-stain plot.
- Apply the matrix to the samples.
- Check the compensated plots and re-draw gates.
- Record the matrix and the settings.
Spectral instruments and compensation
Some instruments measure the full emission spectrum rather than a small number of fixed detector bands. The separation of dyes is then done by unmixing rather than by a traditional compensation matrix. The principle is similar: the measured spectrum is modelled as a combination of the individual dye spectra.
Spectral unmixing still needs single-stain references, and it still has spreading error. The advantage is that dyes with overlapping spectra can sometimes be separated more cleanly. The disadvantage is that the analysis is more complex and depends on good reference spectra.
If you move a panel between a conventional and a spectral instrument, do not assume the settings transfer. Re-run the controls and check the unmixing or compensation in the new system.
Key points
- Compensation corrects spectral spillover mathematically.
- Each fluorophore needs a single-stain control.
- A poor control produces a poor matrix.
- Compensation can increase spread in dim channels.
- Apply compensation before drawing fluorescence gates.
Common mistakes
- Using an unstained sample as a compensation control.
- Reusing a matrix from different voltage settings.
- Ignoring a poor single-stain plot.
- Drawing gates before compensation.
- Treating spreading error as a real positive signal.
When to ask for help
If a single-stain control is poor, if a dim marker disappears after compensation, or if the panel needs redesigning, ask for a review. You can order an analysis or read the gating basics guide. The Flow Cytometry studio reads FCS files and helps inspect channels, and the cell-based assays course covers panel design.
Sources and further reading
- International Society for Advancement of Cytometry
- FlowJo documentation
- NCBI Bookshelf: flow cytometry methods
Written by the Solagene team for research and education. Found an error? Tell us and we will correct it.