Lab & reporting · Step-by-step guide

Lab Data Analysis: a step-by-step guide

Lab Data Analysis groups the bench calculators: qPCR relative quantification, dose–response curves, power and sample size, survival, enzyme kinetics, plate-reader assays and growth curves. This guide explains which tab to use and how to read each fit.

Before you start

  • The plate export or CSV in the layout the chosen tab expects (long or wide for qPCR, a dose–response table, a standard-curve table).
  • A clear definition of the groups, reference genes and control group.
  • The experimental unit and the number of independent replicates, not just technical replicates.
Several tabs have demo buttons, including a two-strain growth-curve demo and a qPCR plate demo.

Step by step

  1. Choose the tab that matches the design

    qPCR for relative expression, Dose–response for IC50/EC50, Power & sample size before an experiment, Survival for time-to-event data, Enzyme kinetics for initial rates, Plate reader for ELISA and growth curves for OD series.

  2. qPCR: load the plate and map the columns

    Drop a long or wide plate CSV, or press Load demo plate. Map sample, gene, group and reference genes. The app computes ΔCt, ΔΔCt, fold change and a 2^−(ΔΔCt ± SD) range.

  3. qPCR: check replicates and statistics

    Technical-replicate outliers are flagged before averaging. The app can run a t-test or ANOVA on ΔCt and reports Holm-adjusted p-values and a best-first gene ranking.

  4. Dose–response: fit a 4PL or 5PL

    Load the dose–response CSV and fit. The table reports IC50 or EC50, Hill slope, top, bottom, asymmetry and a 95% confidence interval; read the interval, not only the point estimate.

  5. Power & sample size: plan before running

    Choose the test family (t, ANOVA, proportions, log-rank or RNA-seq), enter the effect size or CV and the target power. The app returns n per group, events required or the detectable fold change.

  6. Survival and enzyme kinetics

    Survival fits a Cox model with a chosen covariate and needs at least two events. Enzyme kinetics compares Michaelis–Menten, substrate inhibition, Hill and global inhibition fits with AIC.

  7. Plate reader and growth curves

    The plate-reader tab subtracts blanks, fits a 4PL/5PL standard curve and reports LOD/LOQ. Growth curves fit modified Gompertz and logistic models and also report a model-free μmax.

  8. Record the analysis

    Press Add to methods log so the parameters and result travel with the project. Export the tables you will report and keep the raw CSV beside them.

How to read the results

OutputWhat it tells you
qPCR table (ΔCt, ΔΔCt, Fold change, Range, p (Holm))Relative expression against the control after reference-gene normalisation. The range reflects technical variability, not biological variability across independent experiments.
Dose–response table (IC50, Hill slope, 95% CI, R²)The fitted potency and curve shape. A wide confidence interval or a Hill slope far from one is a reason to inspect the raw points.
Power table (Power, n per group, Events required, Detectable fold change)What the design can detect. Use it to justify a sample size, not to claim a result before the experiment.
Growth-curve table (Best model, μ, λ, A, model-free μmax, AIC)The fitted growth parameters and whether a parametric model beat the model-free estimate. Report both when they disagree.

Common problems

A group covariate has more than two groups.
The covariate test expects exactly two groups. Recode the covariate or run the comparison you actually designed.
A standard curve has fewer than three dilutions.
At least three distinct dilutions are required for a curve. Add points or use a different quantification method.
The Cox model has too few events.
At least two events are needed to fit; in practice you need many more for a stable estimate. Report the event count.
The control group is not in the data.
The app names the control group it cannot find. Match the spelling and case in the group column.
The CSV has no usable header or rows.
Each tab expects a header row and at least one data row. Check the delimiter and that the required time, concentration or OD columns exist.

Limits

  • Equal-sized groups in the power tools; dose–response assumes independent replicates and constant variance.
  • qPCR statistics on ΔCt treat technical replicates as the unit unless you supply biological replicates.
  • These are bench-analysis calculators, not a validated clinical or regulatory statistics package.

The app records its tool, version, parameters and input checksum in the methods log. The documentation on reproducibility explains how that record becomes a methods paragraph, and the Report Builder collects the figures into one export.

How to cite this analysis

Cite the Workbench using the Zenodo DOI on the Cite page (/cite). Report the model, weighting, reference genes, control group and the number of independent replicates. Citation, DOI and BibTeX.

Last reviewed: 2026-11-10. If a screen does not match this guide, the app is the source of truth; tell us so the guide can be corrected.