Chemistry & structure · Step-by-step guide

Pharmacokinetics: a step-by-step guide

Pharmacokinetics performs non-compartmental analysis, simulates one- and two-compartment profiles and designs multiple-dose regimens. This guide covers the Non-compartmental, Simulate and Dosing regimens tabs and the assumptions behind each number.

Before you start

  • A concentration–time table with a time column and either a concentration column or one column per subject.
  • The dose, route and dosing interval, with units written down.
  • A decision about whether linear kinetics is a reasonable assumption for the regimen you will simulate.

Step by step

  1. Load the concentration–time data

    Drop a CSV or TSV with a time column and a conc column, or one column per subject. The app rejects an empty table and reports if no numeric time/concentration pairs are found.

  2. Open Non-compartmental

    Enter the dose and route. The app computes AUClast and AUCinf by linear-up/log-down trapezoids, selects the terminal slope λz, and reports half-life, clearance, volume of distribution and mean residence time.

  3. Read the parameter table

    Check AUC %extrap, the λz fit statistics and the sampling window. A large extrapolated fraction means the terminal phase is not well characterised.

  4. Open Simulate

    Choose a one- or two-compartment model and enter the parameters. The app plots the concentration–time profile and the derived Cmax, Tmax and AUC values.

  5. Open Dosing regimens

    Set the dose, interval and number of doses. Multiple-dose superposition predicts accumulation and steady-state troughs, and a loading dose can be calculated for the regimen.

  6. Record the assumptions

    Superposition assumes linear pharmacokinetics. NCA depends on the sampling schedule. Keep both statements with the output.

How to read the results

OutputWhat it tells you
NCA table (Cmax, Tmax, AUClast, AUCinf, AUC %extrap, λz, t½, MRTinf)The exposure and terminal-disposition summary. AUC %extrap is a quality check on the sampling window, and Tmax is the observed time, not a model parameter.
CL, Vz and derived parametersClearance and volume depend on the dose and the AUC or terminal slope. Unit errors propagate directly into these values.
Simulated profileThe model prediction for the parameters you entered. It is not a fit to your data unless the parameters came from that fit.
Steady-state troughs and accumulationWhat superposition predicts at the end of a dosing interval. Check that the regimen and interval match the label you will report.

Common problems

The table has no time or concentration column.
The header needs a time column and either a conc column or one column per subject. Check the delimiter and the spelling.
A profile has fewer than three time points.
At least three time points, and at least three positive concentrations after missing values are removed, are needed for NCA.
The dose is not positive.
Enter a dose greater than zero in the unit stated. A zero or negative dose makes clearance undefined.
The rate constants give a negative discriminant.
The two-compartment parameters are not physically consistent. Recheck the rate constants and units; the app will not invent a complex solution.
The simulated exposure does not match the observed study.
Superposition assumes linear PK. If the drug is nonlinear, or the sampling does not cover the terminal phase, the prediction will not match.

Limits

  • Educational and research tool, not a validated clinical pharmacology package.
  • NCA depends on the sampling schedule and the terminal-phase selection.
  • Multiple-dose superposition assumes linear pharmacokinetics.

The app records its tool, version, parameters and input checksum in the methods log. The documentation on reproducibility explains how that record becomes a methods paragraph, and the Report Builder collects the figures into one export.

How to cite this analysis

Cite the Workbench using the Zenodo DOI on the Cite page (/cite). Report the dose, route, sampling times, λz selection method and the software version. Citation, DOI and BibTeX.

Last reviewed: 2026-11-10. If a screen does not match this guide, the app is the source of truth; tell us so the guide can be corrected.

Need a hand?

Run this analysis with support.

Send the files and the question; we reply with a fixed price and a named analyst. Or keep exploring the free apps.