What the check reports
Paste a forward primer, and optionally a reverse primer. For each primer the page reports length, GC content, nearest-neighbour Tm, the number of G/C bases in the last five positions (the GC clamp), the longest homopolymer run, the longest hairpin stem, the best self-dimer overlap, and the longest complementary run that includes a 3′ end.
For a pair it reports the best cross-dimer overlap and the longest 3′ run between the two primers. An overall label combines the individual and pair risks as low, moderate or high.
Why the 3′ end gets its own column
A polymerase extends from the 3′ end. A few complementary bases at the 3′ end of one primer and the template or the other primer can be enough for extension, so a short 3′ run is more consequential than a longer run buried in the middle. The checker therefore reports the 3′ run separately from the best overall overlap.
GC clamps and homopolymers are shown for the same reason: four or five G/C bases in the last five positions can strengthen priming, while a run of five or more identical bases makes mispriming more likely.
What this cannot tell you
This is a count-based heuristic, not a thermodynamic model. It does not compute a free energy, a salt-corrected duplex stability or a melting temperature for the dimer, and it does not consider the template, the polymerase or the buffer. A low label is not a guarantee that a primer will work.
Use the numbers to compare candidates and to catch obvious problems, then confirm with your supplier’s tool or an established primer-design package before ordering. Count-based check, no free-energy model; confirm with your supplier’s tool.