Reading the curve
A protein’s net charge depends on the pH because each ionisable side chain and terminus protonates or deprotonates. At low pH the positive groups dominate; at high pH the negative groups do. The pH where the net charge is zero is the isoelectric point (pI).
The table lists the charge contributed by each group at the pH you choose, so you can see which residues drive the total. The dot at pH 7.4 marks a typical physiological value.
The pKa set used
This page uses the same set as the Workbench protein-properties calculation: N-terminus 9.69, C-terminus 2.34, K 10.5, R 12.4, H 6.0, D 3.86, E 4.25, C 8.3 and Y 10.07. Positive groups contribute 1 / (1 + 10^(pH − pKa)); negative groups contribute −1 / (1 + 10^(pKa − pH)).
The pKa of a residue in a folded protein can shift substantially with its local environment. A theoretical pI is therefore a planning estimate, not a measurement.
What it is useful for
The charge at a working pH helps plan ion-exchange chromatography (below the pI a protein is positive and binds a cation exchanger; above it, negative and binds an anion exchanger), isoelectric focusing and buffer choice. Near the pI, solubility is often lowest.