Wet lab

Western blot: protocol, controls and troubleshooting

How Western blotting works, a general protocol from lysis to ECL detection, loading controls and normalisation, and fixes for no bands, high background and extra bands.

A Western blot detects one protein in a complex mixture by separating proteins by size on a gel, transferring them to a membrane and probing that membrane with an antibody. It answers two questions at once: is the protein there, and is it the size you expect? This guide covers the principle, a general protocol, how to choose controls and normalise bands, and how to fix the problems everyone meets in their first blots.

How a Western blot works

  1. SDS-PAGE. SDS coats proteins with negative charge and unfolds them, so they migrate through a polyacrylamide gel by size alone. Smaller proteins travel further.
  2. Transfer. An electric field moves the proteins out of the gel onto a nitrocellulose or PVDF membrane, keeping their positions.
  3. Blocking. Milk or BSA covers the empty membrane so antibodies do not stick everywhere.
  4. Immunodetection. A primary antibody binds the target; an enzyme-labelled secondary antibody binds the primary.
  5. Detection. Chemiluminescent substrate (ECL) produces light where HRP sits, captured by an imager or film. Fluorescent secondaries are an alternative that allows two targets on one blot.

A general Western blot protocol

Sample preparation

  • Lyse cells or tissue in RIPA or another lysis buffer with protease (and, for phosphoproteins, phosphatase) inhibitors, on ice.
  • Measure protein concentration with BCA or Bradford and load equal amounts, usually 10–40 µg per lane.
  • Mix with Laemmli buffer containing a reducing agent and heat at 95 °C for 5 minutes (70 °C for membrane proteins that aggregate when boiled).

Gel and transfer

  • Choose the gel percentage for your target: 8% for large proteins (>100 kDa), 10–12% for 20–100 kDa, 15% or gradient gels for small ones. Our SDS-PAGE loading calculator helps with sample volumes.
  • Load a pre-stained molecular weight marker in one lane.
  • Transfer by wet tank (most reliable for large proteins) or semi-dry. Activate PVDF in methanol first.
  • Check transfer with Ponceau S staining before blocking: it shows whether lanes are even and the transfer worked.

Probing

  • Block for 1 hour at room temperature in 5% non-fat milk or 3–5% BSA in TBST. Use BSA for phosphoprotein antibodies, because milk contains casein, a phosphoprotein.
  • Incubate with the primary antibody at the datasheet dilution, often overnight at 4 °C.
  • Wash 3 × 5–10 minutes in TBST.
  • Incubate with the HRP-conjugated secondary antibody, 1 hour at room temperature.
  • Wash again, add ECL substrate and image. Take several exposures so the strongest bands are not saturated.

Controls and normalisation

A blot without controls cannot be interpreted.

  • Positive control: a lysate known to express the protein.
  • Negative control: a knockout, knockdown or non-expressing cell line, which is the best evidence the antibody is specific.
  • Loading control: a housekeeping protein such as GAPDH, β-actin or α-tubulin, or better, total-protein staining. Check that the loading control is not itself changed by your treatment.

For quantification, measure band intensity with ImageJ or the imager software, keep every band within the linear range (no saturated pixels), and divide the target by the loading control. Western blots are semi-quantitative: report relative changes with biological replicates, not absolute amounts.

Troubleshooting Western blots

ProblemLikely causesWhat to try
No bands at allFailed transfer, inactive antibody, wrong secondary speciesCheck Ponceau stain, run a positive control, confirm the secondary matches the primary's host
High backgroundWeak blocking, antibody too concentrated, too little washingBlock longer, dilute antibodies, wash more, try BSA instead of milk
Many non-specific bandsAntibody cross-reactivity, too much protein loaded, degradationUse a validated antibody, load less, add fresh protease inhibitors
Band at the wrong sizeGlycosylation, phosphorylation, cleavage, dimers, splice isoformsCheck UniProt for modifications and isoforms; use reducing conditions
Smiling or distorted bandsGel overheated, uneven salt in samplesRun at lower voltage or in the cold; desalt samples
White (ghost) bandsToo much protein or HRP, substrate exhausted locallyLoad less protein, dilute the secondary
Large proteins missingPoor transfer of big proteinsWet transfer, longer time, add 0.05% SDS to the transfer buffer

Western blot vs ELISA

Use a Western blot when you need to see size, isoforms or modifications, and an ELISA when you need accurate numbers across many samples. Many papers show both.

Learn it hands-on

Western blotting rewards practice more than reading. Our Protein Expression, Purification & Western Blotting course covers expression, purification, SDS-PAGE, transfer and detection at the bench, with a certificate. To check the expected size of your protein before you run a gel, use the free Protein Molecular Weight Calculator.

Try it. SDS-PAGE Loading Calculator: Per-lane volumes and a master mix for SDS-PAGE. Free, and nothing is uploaded. Open the tool.
When to ask for help. If your data or design do not fit a tutorial, order an analysis and we will reply with a fixed price.

Written by the Solagene team for research and education. Found an error? Tell us and we will correct it.